Overview
- Defibrillation energy test range: up to 600 joules and 5000Vpp
- Set adult vs pediatric defibrillation passing range
- Embedded multimeter for AED battery voltage measurement
- Every measurement recorded
- Arbitrary connection without distinguishing polarity
- The product is only 330g and can be operated with one hand
- Plenty of air outlet improve heat dissipation and dust-proof
- Available ECG waves: VF coarse, VF fine, VT fast, VT, AFib, Asystole, NSR
- Compatible Defibrillation Waveform: Biphasic Waveform (Rectilinear Biphasic Waveform, Biphasic Truncated Exponential Waveform, Pulsed Biphasic Waveform), Monophasic Waveform
- Applicable to all AED brands
- Detachable cables for easy storage
- Voltage : Up to 5000 Vp_Accuracy : ± (1% of reading + 2V), typical
- Standalone device operates for simple tests
- The optional paddle box set has outstanding electrical conductivity and mechanical characteristics. The conductive gel drainage grooves are designed for easy cleaning
AED Testing Scenario
Defibrillator Testing Scenario (Optional)
Specification
Energy Measurement Specifications
Items | Specifications |
---|---|
Maximum Energy | Range: Up to 600J |
Voltage | Range: Up to 5000Vp Accuracy: ± (1% of reading + 2V), typical |
Load Resistance | Resistance: 50Ω |
Pulse Width | Range: 1.0 ~ 50.0ms Accuracy: ±0.1ms |
Maximum Average Power | 12W, equivalent to 1 defib pulse of 360J every 30 seconds |
Battery Level (AED Battery) | Measurement Voltage: 0.40 ~ 40.00V Accuracy: ± 0.05V for 5.00 ~ 40.00V |
Battery Level (AED Battery, measured with 200mA load) | Measurement Voltage: 3.60 ~ 40.00V Accuracy: ± 0.05V for 3.60 ~ 40.00V |
General Specifications
Items | Specifications |
---|---|
Temperature | Operating: 0°C ~ 50°C (32°F ~ 122°F) Storage: -20°C ~ +60°C (-4 °F ~ +140°F) |
Humidity | 10% ~ 90% non-condensing |
Communications | Wireless (Low Energy Radio) USB Type-C connector |
Operation Modes | Remote (APP) |
Power | 9V alkaline battery x 1 Battery level display & low power alert on APP |
Mechanical | Housing: ABS Plastic Size (L x W x H): 17.0 x 8.55 x 4.0cm Weight: 330g |
Compliance Specifications
Items | Specifications |
---|---|
Safety Standards | CE: IEC/EN61010-1:2010 + A1:2016; Pollution degree 2 61010-2-030:2017 |
Electromagnetic Compatibility Standards (EMC) | CE: EN61326-1; EN301489‐1 / EN301489‐17 FCC: EMC P15B |
Other Standards | CE: RF EN 300328; EN62311 NCC: RF LP0002 |
Specifications are subject to change without prior notice.
Video
Ordering information
DFS200 Test System
Note: (1) Customization of AED interface cable adapter is available. Please contact WhaleTeq (service@whaleteq.com).
(2) Additional DFS carrying bags can be purchased separately. For details and quotation, please contact WhaleTeq.
Related Information: Use DFS200 Battery Measurement Probe (with load) to check AED battery level
Optional Accessories
Part No. | Image | Description | Quantity |
---|---|---|---|
K27-1800304 | USB Transfer Cable: Type-A to Type-C (Male to Male), 1.8 meter | 1 | |
K29-0900501 | ![]() ![]() | Battery Measurement Probe | 1 |
Optional Paddle Box Set
Part No. | Image | Description | Quantity |
---|---|---|---|
300-DFPDOCK | DFS Tester Docking Base for Defibrillator | 1 | |
E13-070P101 | DFS Tester Defibrillation Receiving Plate | 2 |
Optional Calibration Service and Warranty Extension
Part No. | Description |
---|---|
YY0007 | Model No.: C3 Provides (3) years of calibration service coverage. WhaleTeq equipment can be calibrated to original performance on the basis of (1) year interval. |
YY0008 | Model No.: R3 Extends the limited warranty from (1) year to (3) years. |