Overview
- Intuitive software interface with shock-related information on one screen – the waveform, energy (in Joules), parameters, and characteristic points captured at a sampling rate of 4μs
- Automatically saves complete raw data of the shock waveform to establish a test history
- Outputs ECG waveforms with selectable adult and child modes to achieve high accuracy for testing
- Raw data playback – plays recorded raw data or customized waveforms for repeated verification to facilitate the development process
- Built-in switchable loads ranging from 25Ω to 200Ω
- Repeatability and Reproducibility Analysis – compares the shock waveforms of multiple DUTs or a single DUT to confirm the consistency of quality and reliability, facilitating conducting the endurance test described in IEC 60601-2-4*
- Provides software development kit (SDK) for developing automated testing programs
*Note: The Repeatability and Reproducibility Analysis needs a separate purchase.
AED Testing Scenario
Defibrillator Testing Scenario
Specification
Energy Measurement Specifications
Items | Specifications |
---|---|
Maximum Energy | Range: Up to 600J Accuracy: ± 1% of reading ± 1J for up to 360J; ± 1% of reading ± 1J, typical for 360J ~ 600J |
Voltage | Range: Up to 3000V Accuracy: ± (1% of reading + 1V) for 450V ~ 3000V & -450V ~ -3000V; ± (1% of reading + 2V) for -450V ~ 450V |
Current | Range: 1.2 ~ 100.0A Accuracy: ± (1% of reading + 0.1A) |
Load Resistance | Resistance: 25, 50, 75, 100, 125, 150, 175, 200Ω |
Energy Accuracy | For 50Ω: For other resistance: Note: Maximum energy of monophasic defibrillation may not reach 360J. |
Pulse Width | Range: 1.0 ~ 48.0ms Accuracy: ±0.05ms |
Sample Rate | 250kHz (4μs sample) |
Maximum Average Power | 24W, equivalent to 1 defibrillation pulse of 360J every 15 seconds |
ECG Signal Specifications
Items | Specifications |
---|---|
Ventricular Fibrillation - Coarse | Vp-p = 3mV |
Ventricular Fibrillation - Fine | Vp-p = 0.5mV |
Ventricular Tachycardia (≒180BPM) | Vp-p = 3mV |
Ventricular Tachycardia Plus (≒234BPM) | Vp-p = 3mV |
Atrial Fibrillation | Vp-p = 1.2mV |
Asystole | Vp-p = 0.03mV |
Normal Sinus Rhythm (NSR) (30 ~ 240BPM by 1BPM per step) | Vp-p 0.5 ~ 5.0mV, step 0.5mV |
User-defined Pattern (Max. 5K Sample Rate) | A total capacity of up to 1000 seconds of raw data files with variable duration for each file |
General Specifications
Items | Specifications |
---|---|
Temperature | Operating: 0°C ~ 50°C (32°F ~ 122°F) Storage: -20°C ~ +60°C (-4°F ~ +140°F) |
Humidity | 10% ~ 90% non-condensing |
Communications | USB Type-C connector |
Operation Modes | Remote (PC Software via API and SDK) |
Power | DC12V Power Adaptor |
Mechanical | Housing: ABS Plastic Size (L x W x H): 24.0 x 24.0 x 6.0cm Weight: 1.6kg |
Compliance Specifications
Items | Specifications |
---|---|
Safety Standards | CE: IEC / EN 61010-1:2010 + A1:2016; Pollution degree 2 61010-2-030:2017 |
Electromagnetic Compatibility Standards (EMC) | CE: EN61326-1 FCC: EMC P15B |
*Specifications are subject to change without prior notice.
Ordering information
DFS400 Test System
Model No. | Image | Description |
---|---|---|
300-DFS400 | DFS400 AED/Defibrillator Tester Main Unit | |
S92-0204021 | ![]() | DC12V Power Adaptor |
K22-0500101 | Open-ended AED Cable (Banana Male), 0.5 meter (Black) | |
K22-0500102 | Open-ended AED Cable (Banana Male), 0.5 meter (Red) | |
N61-0210033 | Compact Splicing Connector | |
K27-1800304 | USB Transfer Cable: Type-A to Type-C (Male to Male), 1.8 meter |
Optional Paddle Box Set
Optional Tool
Model No. | Image | Description |
---|---|---|
800-DF07001 | Scan Software and Barcode Scanner (Argox barcode scanner, model no. AS-9400) |
Optional Software Add-On Pack
Model No. | Description |
---|---|
HE0-DF00001 | Repeatability and Reproducibility Analysis for inspecting DUT's quality and performance |
Optional Calibration Service and Warranty Extension
Model No. | Description |
---|---|
C3 | Provides (3) years of calibration service coverage. WhaleTeq equipment can be calibrated to original performance on the basis of (1) year interval. |
R3 | Extends the limited warranty from (1) year to (3) years. |