Origins
When developing patient monitors, manufacturers face challenges in ensuring the accuracy of respiratory monitoring and detecting subtle changes in respiratory signals.
To facilitate product testing, we designed a respiration module compatible with the SECG 5.0 AIO Multi Vital Sign Simulator. This module expands the simulation range of impedance respiratory signals and improves variability resolution.
Individual differences result in varying baseline impedance values, leading to different respiratory signals. With the respiration module, the SECG 5.0 AIO expands its respiratory signal simulation range from the original 500Ω to 2500Ω to a new range of 100Ω to 4500Ω. This allows for simulation from average human impedance values to extreme conditions.
Moreover, by observing respiratory variability, including frequency and amplitude, different respiratory patterns can be recognized. The respiration module expands the respiratory signal variability range of SECG 5.0 AIO to 10Ω, with a minimum step size of 0.05Ω within the range of 0.0Ω to 5Ω. This enables testing of patient monitors' responses to subtle changes in respiratory signals, helping engineers enhance detection sensitivity.
Highlights
Optimizes Measurement Range and Resolution of Impedance Respiratory Signals of SECG 5.0 AIO
- Expands respiratory measurement range of SECG 5.0 AIO from the original 500Ω–2500Ω to a range of 100Ω–4500Ω
-
Optimizes variability resolution of SECG 5.0 AIO from the original 1.0Ω–5.0Ω to a range of 0.0Ω–10.0Ω with a minimum step size of 0.05Ω within the range of 0.0Ω–5Ω
-
Raw data playback — loads and plays clinically recorded or user-defined waveforms to rapidly verify respiratory signal processing systems and algorithms
Note: The respiration module only supports impedance respiratory signal simulation in ECG mode on the SECG 5.0 AIO.
Respiration Parameters
Parameters | Respiration Module Specifications | SECG 5.0 AIO Built-in Respiration Specifications | |
---|---|---|---|
Rate | 1 ~ 200BrPM (Minimum step size: 1BrPM) | 1 ~ 200BrPM (Minimum step size: 1BrPM) | |
Ratio (inspiration:expiration) | 1:1, 1:2, 1:3, 1:4, 1:5 | 1:1, 1:2, 1:3, 1:4, 1:5 | |
Impedance Variations (Δ Ω) | 0.0 ~ 5Ω (Minimum step size: 0.05Ω) 5.0 ~ 10.0Ω (Minimum step size: 0.1Ω) | 1.0 ~ 5.0Ω (Minimum step size: 0.1Ω) | |
Variation Accuracy | ± (2% of setting + 0.1Ω) | ±1% (according to the component's specifications) | |
Impedance Baseline | 100Ω, 200Ω, 500Ω, 1000Ω, 1500Ω, 2000Ω, 2500Ω, 3000Ω, 3500Ω, 4000Ω, 4500Ω | 500Ω, 1000Ω, 1500Ω, 2000Ω, 2500Ω | |
Baseline Accuracy | ±2% | ±5% (including 25kΩ internal resistance of the internal ECG signal line) | |
Respiration Lead | RA, LA, LL | RA, LA, LL, V1~V6 | |
Apnea Selection | 1 ~ 60 sec./min. | 1 ~ 60 sec./min. | |
Noise Add-on | Selection | 50, 60, 100, 120, 150, 180, 200, 240Hz White noise | 50, 60, 100, 120, 150, 180, 200, 240Hz White noise |
Amplitude | 0.01 ~ 5mV (Minimum step size: 0.01mV) | 0.01 ~ 5mV (Minimum step size: 0.01mV) | |
Play Raw Data | Sample Rate | Maximum: 10kHz (able to play customized digital ECG waveforms together with impedance respiratory signals) | Maximum: 20kHz (only ECG raw data can be played; impedance respiration raw data are not supported) |
Wave Modulation | Baseline | 0 ~ 16% (Minimum step size: 1%) | 0 ~ 16% (Minimum step size: 1%) |
Amplitude | 0 ~ 16% (Minimum step size: 1%) | 0 ~ 16% (Minimum step size: 1%) | |
Frequency | 0 ~ 16% (Minimum step size: 1%) | 0 ~ 16% (Minimum step size: 1%) |
Respiration Module
Part No. | Description | Quantity |
---|---|---|
100-EC00006 | Model No.: Respiration module Model Name: Respiration Module Package contents: • Respiration module x 1 • Compound Terminal x 5 • BNC cable (banana male to banana male, 31.5cm, red) x 3 • BNC cable (banana male to banana male, 31.5cm, black) x 1 • DB15 cable (male to female, 30cm) x 1 • Grounding cable (alligator clip to ring terminal, 100cm) x 1 | 1 |
Optional Accessories
Part No. | Description | Quantity |
---|---|---|
K22-0300201 | BNC cable (banana male to banana male) (31.5cm) (red) | 1 |
K22-0300301 | BNC cable (banana male to banana male) (31.5cm) (black) | 1 |
K28-0300301 | DB15 cable (male to female) (30cm) | 1 |
K29-1000801 | Grounding cable (alligator clip to ring terminal) (100cm) | 1 |
N54-0120013 | Compound terminal | 1 |
Optional Calibration Service and Warranty Extension
Part No. | Description |
---|---|
YY0007 | Model No.: C3 Provides (3) years of calibration service coverage. WhaleTeq equipment can be calibrated to original performance on the basis of (1) year interval. |
YY0008 | Model No.: R3 Extends the limited warranty from (1) year to (3) years. |