RDCA Database Comparison Software
RDCA Database Comparison Software

RDCA
Database Comparison Software

A quick tool to compare database test result and perfect algorithm.
Standard Coverage: IEC 60601-2-47, ANSI / AAMI EC57, YY 0885.
Applicable for R&D and compliance testing.
Request a quote Inquiry list

DatasheetDatasheet
User ManualUser Manual

Overview

  • Support comparisons of TAF (Test Annotation File), which is generated by DUT algorithms from either digital or analog database signal input, to RAF (Reference Annotation File).
  • The AI Sync function automatically synchronizes the TAF (Test Annotation File) and RAF (Reference Annotation File) to eliminate their time difference for optimizing comparison results
  • Error data and error timing can be displayed for advanced algorithm improvement
  • Intuitive software interface allows user to complete the comparison within a few mouse clicks
  • Comparison result is identical with PhysioNet WFDB library software and can be exported to a report file

Specification

CategoryDetail
Supported StandardsIEC 60601-2-47, ANSI / AAMI EC57, YY 0885
Supported DatabasesMIT-BIH, AHA, NST, CU, ESC
Supported Test Options – 
17 Required Capabilities
• QRS Se, QRS +P
• VEB Se, VEB +P, VEB FPR
• VEB COU Se, VEB COU +P, VEB S_Run Se, VEB S_Run +P, VEB L_Run Se, VEB L_Run +P
• RMS heart rate error
• % beats missed, % N and S missed, % V missed, % F missed, Total SHUTDOWN time
Supported Test Options – 
25 Optional Capabilities
• SVEB Se, SVEB +P, SVEB FPR
• SVEB COU Se, SVEB COU +P, SVEB S_Run Se, SVEB S_Run +P, SVEB L_Run Se, SVEB L_Run +P
• VF EP Se, VF EP +P, VF DU Se, VF DU +P, VF FPR, VF Time
• AF EP Se, AF EP +P, AF DU Se, AF DU +P, AF FPR, AF Time
• ST EP Se, ST EP +P, ST DU Se, ST DU +P
TAF Format• Binary-MIT annotation (*.atr)
• Text-MIT Label (*.txt)
• Text-AHA Label (*.txt)
• Text-AAMI Label (*.txt)
• Text -AHA 2 fields (*.txt)
• Text -AAMI 2 fields (*.txt)
Supported Time Unit• Sample Index (100Hz ~ 1500Hz)
• Absolute Time
Supported Report Export FormatTXT, CSV, Excel, Word

Ordering information

Part No.Description
HB0-RDBA099Model No.: RDCA Basic
Rhythm database comparison software for 17 capabilities of all arrhythmia algorithm requirements
HB0-RDPR099Model No.: RDCA Pro
Rhythm database comparison software for 17 capabilities of all arrhythmia algorithm requirements and optional 25 capabilities
HB0-RDEN099Model No.: RDCA Enterprise
Rhythm database comparison software for 17 capabilities of all arrhythmia algorithm requirements and optional 25 capabilities
Supports comparison with other databases* besides AHA, MIT-BIH, NST, CU, and ESC

 

◆ The 17 capabilities of all arrhythmia algorithm requirements include QRS, VEB, RMS, and Total SHUTDOWN time. Please refer to item 3 in ''Specification'' for details.
◆ The optional 25 capabilities include SVEB, VF, AF, and ST and exclude HRV. Please refer to item 4 in ''Specification'' for details.

 

*Note: The capabilities and formats of other databases need to align with those of the RDCA to perform the comparison. For details of capabilities, please refer to item 3 and item 4 in ''Specification''.

Related Products