RDCA Database Comparison Software
RDCA Database Comparison Software

RDCA
Database Comparison Software

A quick tool to compare database test result and perfect algorithm.
Standard Coverage: IEC 60601-2-47, ANSI / AAMI EC57, YY 0885.
Applicable for R&D and compliance testing.
Request a quote Inquiry list

DatasheetDatasheet
User ManualUser Manual

Overview

  • Support comparisons of TAF (Test Annotation File), which is generated by DUT algorithms from either digital or analog database signal input, to RAF (Reference Annotation File).
  • The AI Sync function automatically synchronizes the TAF (Test Annotation File) and RAF (Reference Annotation File) to eliminate their time difference for optimizing comparison results
  • Error data and error timing can be displayed for advanced algorithm improvement
  • Intuitive software interface allows user to complete the comparison within a few mouse clicks
  • Comparison result is identical with PhysioNet WFDB library software and can be exported to a report file

Specification

CategoryDetail
Supported StandardsIEC 60601-2-47, ANSI / AAMI EC57, YY 0885
Supported DatabasesMIT-BIH, AHA, NST, CU, ESC
Supported Test Options – 
17 Required Capabilities
• QRS Se, QRS +P
• VEB Se, VEB +P, VEB FPR
• VEB COU Se, VEB COU +P, VEB S_Run Se, VEB S_Run +P, VEB L_Run Se, VEB L_Run +P
• RMS heart rate error
• % beats missed, % N and S missed, % V missed, % F missed, Total SHUTDOWN time
Supported Test Options – 
25 Optional Capabilities
• SVEB Se, SVEB +P, SVEB FPR
• SVEB COU Se, SVEB COU +P, SVEB S_Run Se, SVEB S_Run +P, SVEB L_Run Se, SVEB L_Run +P
• VF EP Se, VF EP +P, VF DU Se, VF DU +P, VF FPR, VF Time
• AF EP Se, AF EP +P, AF DU Se, AF DU +P, AF FPR, AF Time
• ST EP Se, ST EP +P, ST DU Se, ST DU +P
TAF Format• Binary-MIT annotation (*.atr)
• Text-MIT Label (*.txt)
• Text-AHA Label (*.txt)
• Text-AAMI Label (*.txt)
• Text -AHA 2 fields (*.txt)
• Text -AAMI 2 fields (*.txt)
Supported Time Unit• Sample Index (100Hz ~ 1500Hz)
• Absolute Time
Supported Report Export FormatTXT, CSV, Excel, Word

Ordering information

Model No.Description
RDCA BasicRhythm database comparison software for 17 capabilities of all arrhythmia algorithm requirements
RDCA ProRhythm database comparison software for 17 capabilities of all arrhythmia algorithm requirements and optional 25 capabilities
RDCA EnterpriseRhythm database comparison software for 17 capabilities of all arrhythmia algorithm requirements and optional 25 capabilities
Supports comparison with other databases* besides AHA, MIT-BIH, NST, CU, and ESC

 

◆ The 17 capabilities of all arrhythmia algorithm requirements include QRS, VEB, RMS, and Total SHUTDOWN time. Please refer to item 3 in ''Specification'' for details.
◆ The optional 25 capabilities include SVEB, VF, AF, and ST and exclude HRV. Please refer to item 4 in ''Specification'' for details.

 

*Note: The capabilities and formats of other databases need to align with those of the RDCA to perform the comparison. For details of capabilities, please refer to item 3 and item 4 in ''Specification''.

Related Products